Overview.
 
Insulation.
Jacketing.
Thermoplastic.
Crosslinkable.
Halogenfree.
Halogenated.
High temperature
(>125șC/260 F).
PVC 85-A-001TP
Modified lead-free thermoplastic compound based on PVC for automotive wire insulation for 85șC (185F) applications. ISO 6722 Class A, LV 112 Class A, SAE J1127, SAE J1128, Ford, Chrysler, PSA.
PVC 105-A-001TP
Modified lead-free thermoplastic compound based on PVC for automotive wire insulation for 105șC (221F) applications. ISO 6722 Class A, LV 112 Class A, SAE J1127, SAE J1128, Ford, Chrysler, PSA, JASO D 611-94.
RDX 2125-IN-S
Radiation crosslinkable halogenfree flame retardant insulation compound, highly resistant to ozone, weathering, hydrolysis, oils, abrasion and heat pressure Operating temperature -40șC to +125șC
(-40 F to +260 F). UL 3266, UL 3271, Railways.
RDX 3155-IN-S
Radiation crosslinkable flame retardant insulation compound, highly resistant to ozone, weathering, hydrolysis, oils, abrasion and heat pressure Operating temperature -65șC to +155șC (-85 F to +310 F). Suitable for various automotive applications.
RDX 3155-IN-F
Very flexible radiation crosslinkable flame retardant insulation and jacketing compound, highly resistant to ozone, weathering, hydrolysis, oils, abrasion and heat pressure Operating temperature -65șC to +150șC (-85 F to +300 F). UL 3289.
IS-PP-17-11A
Thermoplastic, 125șC, halogenfree flame-retarded compound. PP-based.Excellent mechanical, electrical and abrasion resistant properties. For conductors up to 2.0 mm2. Fibre-optic, off-shore, automotive.
IS-PP-17-21A
Thermoplastic, 125șC, halogenfree flame-retarded compound. PP-based.Excellent mechanical, electrical and abrasion resistant properties. For conductors larger than 2.0 mm2. Fibre-optic, off-shore, automotive.
MX 1090-IN-S
Moisture crosslinkable, silane grafted (Sioplas), non-flame-retarded high performance modified XLPE compound for insulation of bare and tinned copper conductors. For applications such as shipboard and mobile and fixed offshore units, power, telecommunication and control data cables. Curing at ambient temperatures. IEC 60092-351 XLPE, BS 6755 EI5, HD 22.9S2 EI5, IEC 60502-1 XLPE, DIN VDE 0250 Part 503 HI3 and similar specifications
MX 325
Moisture crosslinkable compound (Sioplas), halogenated, insulation and jacketing, 145șC, flexible at - 55șC. Horizontal and VW-1 flame-retarded, LOI 33. UL 3271, UL 3266, etc. Automotive, industrial, appliances, sensor wires
RDX 3144/
RDX 4144
Radiation crosslinkable , low smoke, flame-retarded compounds for dualwall constructions. Flexible, excellent hot oil resistant. For extreme temperature ranges where traditional compounds would fail. Modified polyalkene and modified PVDF. Low corrosive gas emission. Military,industry. MIL-W-81044
TPE 3292-ZHF
Thermoplastic, halogenfree, flameretardant EPDM based compound for insulation and jacketing, requiring good mechanical properties and a low temperature flexibility till - 50șC (58 F). Can be crosslinked by irradiation. Flexible control cables, mass transit cables